25kV Medium Voltage Termination
Class 1 terminator for 1/C 25-28kV extruded dielectric shielded power cable


The Innovative Power Products MVT 2530 series Class I terminators are heatshrinkable 25kV (22-28kV) extruded dielectric, shielded, medium voltage power cable terminations The MVT 2530E series terminations are for applications where the terminator is exposed to the elements such as precipitation or direct outdoor sunlight.

MVT kits provide a lightweight, compact and flexible alternative to porcelain terminators. These features allow the installation of the system in low profile switchgear and other enclosures requiring multiple cable-to-busbar connections. The MVT system does not add any significant weight to the cable, therefore no special hardware is required to support the completed termination.

  • MVT kits are factory engineered to provide fast and easy installation with reliable performance.

    All MVT kits are designed to meet or exceed the requirements of IEEE-48 for Alternating Current Cable Terminations.

  • MVT 2530 kits cover a wide range of conductor sizes and shapes. They accommodate out-of-round or off-tolerance cables in both round and sector shaped conductors. The standard kits fit all types of cable constructions, including: metallic tape shield, drain wire shield, lead covered and Unishield® power cables. Three (3) kit sizes cover all cable sizes from 2 AWG through 1000 kcmil.
MVES050
Electrical Specifications: Related Accessories
 
Test Requirement
Value MVT 2530
AC withstand, 1 minute (60 hz)
65 kV PASS
DC withstand, 15 minutes
105 kV PASS
Discharge Extinction Voltage (<3pC)
21.5 kV > 21.5kV
Impulse withstand 1.2 x 50 μs (crest kV)
150 kV >150kV
Wet withstand , 10 seconds
60 kV PASS
Dry withstand, 6 hours
55 kV PASS
Continuous current rating
= Cable = Cable
   
Bill of Materials: (Std. Pkg: 3 kits) terminates 1 - 1/C cable end
 
Key
Item Description
Quantity Supplied
1
Field Control Material
1 strip In All Kits
2
Field Control Tubing
1 tube In All Kits
3
Non-Tracking Tubing
1 tube In All Kits
4
Sealant Strips
as required In All Kits
-
Installation Guide
1 each In All Kits
       
Options: Mod. Kits: requirements for one kit
     
Key
Item Description
Quantity Nomenclature
5
Non-Tracking Sheds
1 piece E - Emod Kit**
6
Sealed Ground Kits
1 piece G - Gmod Kit**
-
Cable Cleaning Kit (Not Shown)
1 kit P - Pmod Kit**
-
Terminal Lugs
1 piece Factory Quoted*



  • To download a PDF copy of the data sheet Click here.

    For a complete PDF of the current IPP catalog Click Here. If you would like the catalog in a printed version, please go to the "Catalog Request" page via the link at the top of the page.



The kits are packaged to provide three (3) single-core terminations. Everything is included to terminate three single cores less the terminal lugs and external grounding components. External grounding components can be included as a kit option. Connectors can be supplied in the kits; subject to factory quote.



  • MVT 2530: Price List PL-642

25kv Selection Guide
   
Conductor Range Catalog #

Insulation

Diameter

Jacket
Diameter Max.

2 - 3/0 AWG MVT 2531 0.80 - 1.10 1.50
4/0 - 350 kcmil MVT 2532 1.00 - 1.31 1.76
500 - 1000 kcmil MVT 2533 1.20 - 2.16 2.26
       

All dimensions in inches unless shown otherwise


Ordering Information

1. Select the kit catalog number by the cable size. A standard package contains everything needed to terminate one (1) single-core (1/C) cables, less the connectors, for sheltered (indoor) use. Confirm the dimensions when at the extremes of the size range.
SPACE
2. Add the mod kit letter designation as needed to change the base kit:

E - sheds are required for exposed
(outdoor) environments. (Emod)
P - cable cleaning kit (Pmod)
G - sealed grounding kit (Gmod)
     
Examples
     
Example 1:
For 1/C, 2/0 AWG, 25kV cable to be installed in an exposed (outdoor environment, using a sealed grounding kit (Gmod) and a cable cleaning kit:

MVT 2531 EGP - Product# Breakdown
25 -
25kV Class 1 Termination base kit
31 -
3-1/C term./box and kit size
E -
Exposed, Non-tracking Sheds (Emod)
G -
Sealed grounding kit (Gmod)
P -
Cleaning/prep kit (Pmod)

  Example 2:
For 1/C, 500 kcmil, 25kV cable to be installed in a sheltered (indoor) environment, using a sealed grounding kit (Gmod) and a cable cleaning kit:

MVT 2533 GP - Product# Breakdown
25 -
25kV Class 1 Termination base kit
31 -
3-1/C term./box and kit size
G -
Sealed grounding kit (Gmod)
P -
Cleaning/prep kit (Pmod)



* CONNECTORS: To have connectors supplied in the kits, please refer to Section 5 in this catalog for connector selection information. The connectors must be ordered separately but can be packaged within the kits if detailed information is supplied.
** Supplied if specified.
*** WRAPAROUND SLEEVE with stainless steel channel– Contact IPP for more information.


QUESTIONS OR QUOTES EMAIL US AT: sales@ippcorp.com or CALL TOLL FREE 1-800-544-4626